Laboratory hydrometer, type 1, DIN 12791 (old), 0,630-0,715:0,001g/cm³,...
Prekė gali skirtis nuo prekės, parodytos nuotraukoje
Components:
- H820292
Laboratory hydrometer, type 2, DIN 12791 (old), 0,715-0,788:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820294
Laboratory hydrometer, type 3, DIN 12791 (old), 0,788-0,860:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820296
Laboratory hydrometer, type 4, DIN 12791 (old), 0,860-0,930:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820298
Laboratory hydrometer, type 5, DIN 12791 (old), 0,930-1,000:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820300
Laboratory hydrometer, type 6, DIN 12791 (old), 1,000-1,110:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820302
Laboratory hydrometer, type 7, DIN 12791 (old), 1,090-1,210:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820304
Laboratory hydrometer, type 8, DIN 12791 (old), 1,190-1,310:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820306
Laboratory hydrometer, type 9, DIN 12791 (old), 1,290-1,410:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820308
Laboratory hydrometer, type 10, DIN 12791 (old), 1,390-1,510:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820310
Laboratory hydrometer, type 11, DIN 12791 (old), 1,490-1,610:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820312
Laboratory hydrometer, type 12, DIN 12791 (old), 1,600-1,720:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820314
Laboratory hydrometer, type 13, DIN 12791 (old), 1,720-1,842:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration - H820316
Laboratory hydrometer, type 14, DIN 12791 (old), 1,842-2,000:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration
Laboratory hydrometer, type 1, DIN 12791 (old), 0,630-0,715:0,001g/cm³, accuracy +/- 1 scale division, 255mm long, reference temperature 20°C, without thermometer, reading below, suitable for calibration
| (-) Techniniai duomenys: | |
|---|---|
| Ilgis: | 255 mm |
| Minimali vertė: | 0,630 |
| Didžiausia skalės vertė: | 0,715 |
| Skalės padalos: | 0,001 g/cm³ |
| (-) Compliance information: | |
|---|---|
| WEEE obligation: | Ne |
-
- Gamintojas: Amarell
- Prekės numeris: H820290
- Kategorija: Areometrai
Show all Areometrai from Amarell - Kainos pasiūlymo galiojimas: 31.12.2026
- Atnaujinta: 31.12.2025